Overview and Problem Report (PR) fixes
The NX Nastran 10.1 maintenance release includes the following fixes.
PR# Problem
Reported Problem Description
1128190 V10.0
SOL 401 Creep – The stress oscillates with a constant
load unless KUPDATE=1 (Full Newton-Raphson) is
defined on the NLCNTL bulk entry.
1128682 V10.0 SOL 401 Creep+Plasticity – A model failed to solve with
SMP=4, but solved fine for serial.
8252363 V10.0 SOL 401 – A model had difficulties solving a creep
analysis.
8257119 V10.0
SOL 401 – Receiving the error message MOMENT IS
NOT SUPPORTED as a result of applying a load with
the MOMENT bulk entry.
7200246 V10.0
SOL 401 in the context of a NX 10 coupled multiphysics
solution – output occurred for time steps in which output
was not requested.
In addition to the fixes listed above, there are SOL 401 improvements in NX Nastran
10.1 that improve the general solution performance, and specifically improve the
performance of creep, nonlinear iteration schemes, contact, and bolt preload. Many of
these improvements were made while tuning specific models. As a result, you may not
necessarily see a performance improvement with your models.
2247218 V9.0
SOL 106 – Membrane Force was output as zero in a
nonlinear analysis. A workaround is to set sys(500)=1 to
output mechanical strain instead of the total strain.
7208138 V9.0
SOL 112 – Error in displacement output with MODACC
and WMODAL. A workaround is to eliminate the
parameters MODACC, DDRMM and WMODAL from the